A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 11.0 · diversity 6.5 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
2 source links · newest first
Security experts discovered a critical vulnerability in GE Multilin SR that poses a serious threat to the power grid worldwide. A team of researchers from New York University has found a serious vulnerability in some of GE Multilin SR protection relays that poses a serious threat to power grid. The experts will provide further details about the […]
newssecurityaffairs.comApr 28, 2017, 5:48 PMA critical vulnerability that affects some of GE’s protection relays poses a serious threat to the power grid, researchers have claimed. The vendor has started releasing patches for the security hole.
newswww.securityweek.comApr 28, 2017, 11:41 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2024-45273CVSS 8.4 · High
An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
- CVE-2024-8455CVSS 8.1 · High
The swctrl service is used to detect and remotely manage PLANET Technology devices. For certain switch models, the authentication tokens used during communication with this servic…
- CVE-2024-37187CVSS 6.8 · Medium
Advantech ADAM-5550 share user credentials with a low level of encryption, consisting of base 64 encoding.
- CVE-2024-34542CVSS 6.9 · Medium
Advantech ADAM-5630 shares user credentials plain text between the device and the user source device during the login process.
- CVE-2024-45394CVSS 8.8 · High
Authenticator is a browser extension that generates two-step verification codes. In versions 7.0.0 and below, encryption keys for user data were stored encrypted at-rest using onl…
- CVE-2024-30119CVSS 3.7 · Low
HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection.