Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 11.0 · diversity 5.0 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
2 source links · newest first
Rockwell Automation is concerned about internet-exposed ICS due to heightened geopolitical tensions and adversarial cyber activity globally.
newswww.securityweek.comMay 22, 2024, 1:16 PMResearchers at industrial cybersecurity firm Claroty have identified two serious vulnerabilities that could allow malicious actors to launch Stuxnet-style attacks against programmable logic controllers (PLCs) made by Rockwell Automation.
newswww.securityweek.comApr 1, 2022, 11:27 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2024-8626CVSS 8.7 · High
Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multi…
- CVE-2024-5659CVSS 8.3 · High
Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnera…
- CVE-2024-3493CVSS 8.6 · High
A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (…
- CVE-2022-1797CVSS 6.8 · Medium
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a ma…
- CVE-2024-6207CVSS 8.7 · High
CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html and send a specially crafted CIP message to the device. If exploite…
- CVE-2024-6077CVSS 8.7 · High
A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device w…