CVE detail
CVE-2024-12297
Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 6.9 · diversity 5.0 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
1 source links · newest first
Noteworthy stories that might have slipped under the radar: Switzerland requires disclosure of critical infrastructure attacks, ESP32 chips don’t contain a backdoor, MassJacker cryptojacking malware.
newswww.securityweek.comMar 14, 2025, 12:41 PM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2026-7161CVSS 9.3 · Critical
An insufficient encryption vulnerability exists in the Device Authentication functionality of GeoVision GV-IP Device Utility 9.0.5. Listening to broadcast packets can lead to cred…
- CVE-2026-42363CVSS 9.3 · Critical
An insufficient encryption vulnerability exists in the Device Authentication functionality of GeoVision GV-IP Device Utility 9.0.5. Listening to broadcast packets can lead to cred…
- CVE-2025-59093CVSS 8.5 · High
Exos 9300 instances are using a randomly generated database password to connect to the configured MSSQL server. The password is derived from static random values, which are concat…
- CVE-2025-7020CVSS 5.1 · Medium
An incorrect encryption implementation vulnerability exists in the system log dump feature of BYD's DiLink 3.0 OS (e.g. in the model ATTO3). An attacker with physical access to th…
- CVE-2025-25983CVSS 3.4 · Low
An issue in Macro-video Technologies Co.,Ltd V380 Pro android application 2.1.44 and V380 Pro android application 2.1.64 allows an attacker to obtain sensitive information via the…
- CVE-2024-9138CVSS 8.6 · High
Moxa’s cellular routers, secure routers, and network security appliances are affected by a high-severity vulnerability, CVE-2024-9138. This vulnerability involves hard-coded crede…