CVE-2025-31929
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 6.9 · diversity 5.0 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
1 source links · newest first
- https://cert-portal.siemens.com/productcert/html/ssa-556937.htmlcert-portal.siemens.com
No excerpt available.
Vendor Advisorycert-portal.siemens.comMay 13, 2025, 10:15 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2025-34503CVSS 7.0 · High
Deck Mate 1 executes firmware directly from an external EEPROM without verifying authenticity or integrity. An attacker with physical access can replace or reflash the EEPROM to r…
- CVE-2025-34502CVSS 7.0 · High
Deck Mate 2 lacks a verified secure-boot chain and runtime integrity validation for its controller and display modules. Without cryptographic boot verification, an attacker with p…
- CVE-2025-5834CVSS 7.8 · High
Pioneer DMH-WT7600NEX Missing Immutable Root of Trust in Hardware Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to bypass authentication on a…
- CVE-2025-2762CVSS 7.8 · High
CarlinKit CPC200-CCPA Missing Root of Trust Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of…
- CVE-2024-8357CVSS 7.8 · High
Visteon Infotainment App SoC Missing Immutable Root of Trust in Hardware Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges…
- CVE-2024-30111CVSS 3.3 · Low
HCL DRYiCE AEX product is impacted by Missing Root Detection vulnerability in the mobile application. The mobile app can be installed in the rooted device due to which malicious…