CVE detail
CVE-2026-33892
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 6.9 · diversity 5.0 · KEV 0.0 · OTX 0.0 · PoC 0.0
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
1 source links · newest first
- https://cert-portal.siemens.com/productcert/html/ssa-609469.htmlcert-portal.siemens.com
No excerpt available.
Vendor Advisorycert-portal.siemens.comApr 14, 2026, 9:16 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
0 repository references · best confidence N/A · max 0 stars
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2026-62427CVSS 8.8 · High
[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] To manage the system, sysctl and platform operati…
- CVE-2026-9597CVSS 5.4 · Medium
Mattermost versions 11.7.x <= 11.7.2, 11.6.x <= 11.6.4 fail to verify whether a guest account is deactivated before creating a session in the magic-link token login path, which al…
- CVE-2026-9571CVSS 5.9 · Medium
Mattermost versions 11.7.x <= 11.7.2, 11.6.x <= 11.6.4, 10.11.x <= 10.11.19 fail to invalidate OAuth refresh tokens upon user account deactivation, which allows a deactivated user…
- CVE-2026-35159CVSS 5.3 · Medium
Dell Client Platform BIOS contains an Authentication Bypass by Primary Weakness vulnerability. An unauthenticated attacker with physical access could potentially exploit this vuln…
- CVE-2026-10539CVSS 9.5 · Critical
A Control-M/Server communication command does not sufficiently filter or sanitize user-supplied input. Under certain conditions, this issue may allow an unauthenticated attacker t…
- CVE-2026-41052CVSS 9.4 · Critical
Improper privilege handling could be used by users with Project Owner role to escalate privileges, in Rancher versions 2.14 before 2.14.2, 2.13 before 2.13.6, and 2.12 before 2.12…