CVE detail
CVE-2026-5156
A vulnerability was determined in Tenda CH22 1.0.0.1. This impacts the function formQuickIndex of the file /goform/QuickIndex of the component Parameter Handler. This manipulation of the argument mit_linktype causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 17.9 · diversity 11.5 · KEV 0.0 · OTX 0.0 · PoC 4.5
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
5 source links · newest first
- https://www.tenda.com.cn/www.tenda.com.cn
No excerpt available.
Third Party Advisorywww.tenda.com.cnMar 31, 2026, 12:16 AM - https://vuldb.com/vuln/354188/ctivuldb.com
No excerpt available.
Exploitvuldb.comMar 31, 2026, 12:16 AM - https://vuldb.com/vuln/354188vuldb.com
No excerpt available.
Exploitvuldb.comMar 31, 2026, 12:16 AM - https://vuldb.com/submit/780208vuldb.com
No excerpt available.
Exploitvuldb.comMar 31, 2026, 12:16 AM No excerpt available.
Exploitgithub.comMar 31, 2026, 12:16 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
1 repository references · best confidence 0.90 · max 0 stars
- Litengzheng/vuldb_newHigh confidencegithubNVD Exploit reference0 starsDiscovered Jul 17, 2026, 12:20 PM
NVD labels the source link as Exploit; this is not independent verification of the repository's code.
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2026-5204CVSS 7.4 · High
A vulnerability was determined in Tenda CH22 1.0.0.1. Affected is the function formWebTypeLibrary of the file /goform/webtypelibrary of the component Parameter Handler. This manip…
- CVE-2026-5155CVSS 7.4 · High
A vulnerability was found in Tenda CH22 1.0.0.1. This affects the function fromAdvSetWan of the file /goform/AdvSetWan of the component Parameter Handler. The manipulation of the…
- CVE-2026-5152CVSS 7.4 · High
A vulnerability was detected in Tenda CH22 1.0.0.1. Impacted is the function formCreateFileName of the file /goform/createFileName. Performing a manipulation of the argument fileN…
- CVE-2025-9748CVSS 8.7 · High
A vulnerability was determined in Tenda CH22 1.0.0.1. Affected by this issue is the function fromIpsecitem of the file /goform/IPSECsave of the component httpd. Executing manipula…
- CVE-2025-5685CVSS 8.7 · High
A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the ar…
- CVE-2025-5619CVSS 8.7 · High
A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manip…