CVE detail
CVE-2026-8263
A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.
Buzz score
Why this CVE is surfacing
This all-time snapshot uses the same composite formula as Trending across a 30-year evidence window, rather than a current rolling window.
Buzz score components · mention 17.9 · diversity 11.5 · KEV 0.0 · OTX 0.0 · PoC 4.5
Why it matters now
Mention timeline
- Total mentions
- 0
- within the 30d window
- Peak daily
- 0
- highest bucket
Evidence
Source links by recency
5 source links · newest first
- https://www.tenda.com.cn/www.tenda.com.cn
No excerpt available.
Third Party Advisorywww.tenda.com.cnMay 11, 2026, 2:16 AM - https://vuldb.com/vuln/362560/ctivuldb.com
No excerpt available.
Exploitvuldb.comMay 11, 2026, 2:16 AM - https://vuldb.com/vuln/362560vuldb.com
No excerpt available.
Exploitvuldb.comMay 11, 2026, 2:16 AM - https://vuldb.com/submit/810074vuldb.com
No excerpt available.
Exploitvuldb.comMay 11, 2026, 2:16 AM No excerpt available.
Exploitgithub.comMay 11, 2026, 2:16 AM
Exploit code
Public exploit repository references
Public PoC repositories are third-party, potentially unsafe artifacts. Treat their code as untrusted and use it only on authorized systems in an isolated, least-privilege environment. cvebuzz does not execute the code or verify that an exploit works.
1 repository references · best confidence 0.90 · max 0 stars
- yaoyue123/iotHigh confidencegithubNVD Exploit reference0 starsDiscovered Jul 20, 2026, 6:20 PM
NVD labels the source link as Exploit; this is not independent verification of the repository's code.
Related records
Similar CVEs
6 related CVEs with shared weakness or product evidence
- CVE-2024-2853CVSS 6.3 · Medium
A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg.…
- CVE-2024-2764CVSS 8.8 · High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The mani…
- CVE-2024-2763CVSS 8.8 · High
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The mani…
- CVE-2024-2711CVSS 8.8 · High
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter.…
- CVE-2024-2710CVSS 8.8 · High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWi…
- CVE-2024-2709CVSS 8.8 · High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The ma…